Artigo em Inglês | MEDLINE | ID: mdl-38157151

RESUMO

BACKGROUND: We investigated the preclinical safety and efficacy of ventricular pulsed field ablation (PFA) using a family of novel, 6-/8-Fr, linear, and spiral PFA/mapping catheters (CRC EP, Inc). METHODS: QRS-gated, bipolar PFA (>2.0 kV) was performed in 10 healthy swine. Altogether, 20 endocardial and epicardial right and left ventricular applications were delivered. The catheters were inserted through an 8.5-Fr steerable introducer. The intensity of skeletal muscle activation was quantified using an accelerometer. Lesions were assessed by pre- versus post-PFA electrogram analysis, pacing threshold, 3D voltage mapping, necropsy, and histology. The swine rete mirabile, liver and kidneys were examined for embolic events. RESULTS: All applications were single-shot (56 ± 18 s) without catheter repositioning. Minimal microbubbling was observed without significant skeletal muscle stimulation (mean acceleration 0.05 m/s2) or ventricular tachyarrhythmias. There was significant reduction in post- versus pre-PFA electrogram amplitude (0.5 ± 0.2 mV versus 3.2 ± 0.9 mV, P < 0.001) with a marked increase in pacing threshold (>20 mA versus 7.5 ± 2.9 mA, P < 0.001). All lesions were large and durable up to 28 days, measuring 32 ± 5 mm (length), 27 ± 8 mm (width), and 8 ± 3 mm (depth) using the spiral catheters and 43 ± 1 mm (length), 7 ± 1 mm (width), and 8 ± 1 mm (depth) using the linear catheters. Despite higher waveform voltages and prolonged applications, no thermal effects were detected at necropsy/histology. Moreover, gross and microscopic examinations revealed no evidence of thromboembolism, vascular or collateral injury. CONCLUSIONS: A novel, QRS-gated PFA system using linear and spiral PFA catheters is capable of creating large and durable ventricular lesions in vivo without significant microbubbling, ventricular arrhythmias or thromboembolism.

2.
J Cardiovasc Electrophysiol ; 34(11): 2203-2212, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37464948

RESUMO

INTRODUCTION: Pulsed field ablation (PFA) is a nonthermal ablative strategy that achieves cell death via electroporation. Herein, we investigated the preclinical safety and efficacy of PFA using two novel 8-French, 16-electrode spiral PFA/mapping catheters (ElePulse; CRC EP, Inc.). METHODS: Bipolar PFA (>1.8 kV) was performed using 30 s, single-shot, QRS-gated applications. Altogether, 94 atrial structures were ablated in 23 swine, one canine, and one ovine, including right and left atria and atrial appendages, pulmonary veins, and superior and inferior (IVC) vena cavae. We also examined the impact of PFA on the phrenic nerve (14 swine) and on a deviated esophagus after delivery of PFA from inside the IVC (five swine). RESULTS: All applications were single-shot without catheter repositioning. Minimal microbubbling was observed without significant skeletal muscle twitching/activation (mean acceleration: 0.05 m/s2 ). There was a marked reduction in post-PFA versus pre-PFA atrial electrogram amplitude (0.17 ± 0.21 vs. 1.18 ± 1.08 mV; p < .0001). Lesion durability was demonstrated up to 3 months in all targeted tissues. Histologically, lesions were contiguous and transmural, except in the atrial appendage, and without any thermal effects. Magnetic resonance, gross, and histologic examinations of the brain, rete mirabile, and kidneys revealed no thromboembolism. No acute/long-term phrenic nerve dysfunction was encountered. Although within 2 h of ablation, histologic examinations of the esophagus revealed acute PFA-related changes in the muscular layer, these completely resolved by 21 ± 5 days. CONCLUSION: A novel, single-shot, spiral PFA system is capable of safely creating large, durable atrial lesions without significant adverse effects on the phrenic nerve or the esophagus.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Animais , Cães , Ovinos , Suínos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Terapia de Eletroporação Irreversível , Ablação por Cateter/efeitos adversos , Terapia com Eletroporação , Resultado do Tratamento
3.
J Ultrasound Med ; 31(2): 247-56, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22298868

RESUMO

OBJECTIVES: The primary objective was to test in vivo for the first time the general operation of a new multifunctional intracardiac echocardiography (ICE) catheter constructed with a microlinear capacitive micromachined ultrasound transducer (ML-CMUT) imaging array. Secondarily, we examined the compatibility of this catheter with electroanatomic mapping (EAM) guidance and also as a radiofrequency ablation (RFA) catheter. Preliminary thermal strain imaging (TSI)-derived temperature data were obtained from within the endocardium simultaneously during RFA to show the feasibility of direct ablation guidance procedures. METHODS: The new 9F forward-looking ICE catheter was constructed with 3 complementary technologies: a CMUT imaging array with a custom electronic array buffer, catheter surface electrodes for EAM guidance, and a special ablation tip, that permits simultaneous TSI and RFA. In vivo imaging studies of 5 anesthetized porcine models with 5 CMUT catheters were performed. RESULTS: The ML-CMUT ICE catheter provided high-resolution real-time wideband 2-dimensional (2D) images at greater than 8 MHz and is capable of both RFA and EAM guidance. Although the 24-element array aperture dimension is only 1.5 mm, the imaging depth of penetration is greater than 30 mm. The specially designed ultrasound-compatible metalized plastic tip allowed simultaneous imaging during ablation and direct acquisition of TSI data for tissue ablation temperatures. Postprocessing analysis showed a first-order correlation between TSI and temperature, permitting early development temperature-time relationships at specific myocardial ablation sites. CONCLUSIONS: Multifunctional forward-looking ML-CMUT ICE catheters, with simultaneous intracardiac guidance, ultrasound imaging, and RFA, may offer a new means to improve interventional ablation procedures.


Assuntos
Cateterismo Cardíaco/instrumentação , Ablação por Cateter/instrumentação , Ecocardiografia/instrumentação , Transdutores , Ultrassonografia de Intervenção/instrumentação , Animais , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Desenho de Equipamento , Fluoroscopia , Suínos
4.
Artigo em Inglês | MEDLINE | ID: mdl-21768025

RESUMO

A method is introduced to monitor cardiac ablative therapy by examining slope changes in the thermal strain curve caused by speed of sound variations with temperature. The sound speed of water-bearing tissue such as cardiac muscle increases with temperature. However, at temperatures above about 50°C, there is no further increase in the sound speed and the temperature coefficient may become slightly negative. For ablation therapy, an irreversible injury to tissue and a complete heart block occurs in the range of 48 to 50°C for a short period in accordance with the well-known Arrhenius equation. Using these two properties, we propose a potential tool to detect the moment when tissue damage occurs by using the reduced slope in the thermal strain curve as a function of heating time. We have illustrated the feasibility of this method initially using porcine myocardium in vitro. The method was further demonstrated in vivo, using a specially equipped ablation tip and an 11-MHz microlinear intracardiac echocardiography (ICE) array mounted on the tip of a catheter. The thermal strain curves showed a plateau, strongly suggesting that the temperature reached at least 50°C.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Ablação por Cateter/métodos , Ecocardiografia/métodos , Processamento de Sinais Assistido por Computador , Animais , Ablação por Cateter/efeitos adversos , Estudos de Viabilidade , Temperatura Alta , Complicações Intraoperatórias/prevenção & controle , Miocárdio/citologia , Suínos
5.
Artigo em Inglês | MEDLINE | ID: mdl-21097106

RESUMO

Capacitive micromachined ultrasonic transducer (CMUT) arrays are conveniently integrated with frontend integrated circuits either monolithically or in a hybrid multichip form. This integration helps with reducing the number of active data processing channels for 2D arrays. This approach also preserves the signal integrity for arrays with small elements. Therefore CMUT arrays integrated with electronic circuits are most suitable to implement miniaturized probes required for many intravascular, intracardiac, and endoscopic applications. This paper presents examples of miniaturized CMUT probes utilizing 1D, 2D, and ring arrays with integrated electronics.


Assuntos
Eletrônica Médica/instrumentação , Imageamento Tridimensional/instrumentação , Microtecnologia/instrumentação , Transdutores , Ultrassom/instrumentação , Animais , Cateterismo , Eletrocardiografia , Imagens de Fantasmas , Sus scrofa